Crestron® Ethernet to Cresnet® Bridge with built-in network diagnostics and versatile power management
USB Port | Yes |
---|
Depth (in.) | 2.3 |
---|---|
Width (in.) | 6.33 |
Height (in.) | 3.61 |
Amount Of Lan Ports | 1 |
Number Of Lan Ports | 1 |
Product Weight (lbs.) | 0.62 |
Call for Best Price
Works with a Crestron® 3-Series Control System® to maximize Cresnet® network reliability and performance. Enables Cresnet data over high-speed Ethernet and features two isolated Cresnet subnets, built-in network diagnostics, and versatile power management.
The Ethernet to Cresnet® Bridge (DIN-CENCN-2) works with any Crestron® 3-Series Control System® to maximize the reliability and robustness of the Cresnet network. It offers a more sophisticated solution than a Cresnet block or hub, providing two isolated subnets and built-in diagnostics, plus versatile power distribution options and a convenient DIN rail form factor.NOTE: The DIN-CENCN-2 is compatible with 3-Series® control systems only.
Cresnet is the communications backbone for many Crestron keypads, lighting controls, shade motors, thermostats, occupancy sensors, and other devices that don’t require the higher speed of Ethernet. It provides a dependable and flexible wiring solution, allowing multiple devices to be wired together in parallel using both home-run and daisy-chain topologies. The Cresnet bus distributes bidirectional data communication and 24VDC power to each device over a single 4-conductor cable.
Adding one or more Ethernet to Cresnet bridges to a 3-Series Control System enables the distribution of Cresnet over high-speed Ethernet. The increased bandwidth afforded by Ethernet reduces latency for overall improved speed and performance. And, by leveraging existing LAN infrastructure in any facility, wiring distances can be extended easily while potentially reducing the overall wiring requirements. One or more bridges can be deployed on a single control system, and they can even be addressed by more than one control system, affording incredible flexibility in system design and functionality.
The DIN-CENCN-2 provides two isolated subnets. Each subnet behaves as a Cresnet master with its own unique address space. A maximum of 20 Cresnet devices is supported per subnet, and each subnet furnishes six Cresnet connectors for easy termination of multiple lines.
Proper power distribution is key to a reliable Cresnet network. To facilitate proper powering, the DIN-CENCN-2 offers versatile, scalable power management using one or two external 24VDC Cresnet power supplies. For more details, refer to the “Power Requirements” section of the specifications.The DIN-CENCN-2 configures itself automatically based on the power supplies connected. Built-in protection intelligently monitors the load and wiring conditions on each subnet, and shuts down power to either subnet in case of an overload, wiring fault, or power supply failure. If such an error occurs, only the subnet with the error is shut down, leaving the other subnet fully operable.
Many common control system problems are caused by wiring faults, insufficient power, or too many devices. The latter is resolved by increasing bandwidth using Ethernet and limiting the number of devices that can be connected to each subnet. For the other issues, the DIN-CENCN-2 provides a full set of diagnostic tools to help identify and resolve them easily. From the unit’s front panel, an installer can press the “TEST” button and observe the LED indicators to see if there are any error codes. This allows wiring problems to be identified before ever powering up the control system. More complete details can be viewed and analyzed using a Web browser or Crestron Toolbox™ software. In a functioning control system, sporadically occurring errors caused by cut or faulty wires, disconnected devices, or failed power supplies can be reported to the control system in real-time to provide error notifications via a touch screen, mobile device, email, text message, SNMP, or Crestron Fusion® enterprise management software. Insertion of an SD memory card (not included) enables logging of Cresnet activity and errors over time, making it easier to diagnose intermittent issues that can’t be duplicated on demand.
The DIN-CENCN-2 is designed to snap onto a standard 35 mm DIN rail for installation in a wall mount enclosure or on any flat surface. DIN rail mounting affords a very space-efficient, cost-effective, and modular solution for configuring complete control systems using a DIN-AP3 processor along with additional Crestron and third-party DIN rail mountable devices.
Maximizes Cresnet® network reliability and performance
Designed for use with any Crestron® 3-Series Control System®
Enables Cresnet data communications over high-speed Ethernet
Provides two isolated Cresnet subnets
Supports 20 Cresnet devices per subnet
Supports 3000 feet (914 m) aggregate cable length per subnet
Includes intelligent power management for each subnet
Features built-in network diagnostics tools
Allows testing of network wiring, power, and communications
Allows detailed error analysis via software or Web browser
Allows real-time reporting of errors via the control system
Allows logging of Cresnet activity and errors over time
9M wide DIN rail mountable
Depth (in.) | 2.3 |
Width (in.) | 6.33 |
Height (in.) | 3.61 |
Amount Of Lan Ports | 1 |
Number Of Lan Ports | 1 |
Product Weight (lbs.) | 0.62 |
USB Port: | Yes |